User Manual
Chapter 4 - Operation and Administration Using the CLI Managing BSs
4Motion 592 System Manual
Command
Syntax
npu(config-bs-66053)# triggersetup [hysteresismargin <(0 to 255
StepSize 1)> ] [timetotrigger <(0 to 255 StepSize 1)> ]
[avgduration-rssi <(0 to 255 StepSize 1)> ] [avgduration-cinr <(0
to 255 StepSize 1)> ] [avgduration-rtd <(0 to 255 StepSize 1)> ]
Privilege
Level
10
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
[hysteresismargin <(0
to 255 StepSize 1)> ]
The CINR hysteresis in dB
for adding or deleting
neighbors. The hysteresis
margin is used by the MS
in the decision whether to
include a neighbor BS in a
list of possible target BSs.
Optional 5 0 - 255
[timetotrigger <(0 to
255 StepSize 1)> ]
The minimum time in
milliseconds between
adding or deleting a
neighbor. It is the time
that the MS takes to
decide whether to select a
neighbor BS as a possible
target BS and is
applicable only for HHO.
Optional 50 0 - 255
[avgduration-rssi <(0
to 255 StepSize 1)> ]
The default RSSI average
duration for triggers, in
milliseconds
Optional 50 0 - 255
[avgduration-cinr <(0
to 255 StepSize 1)> ]
The default CINR average
duration for triggers, in
milliseconds
Optional 50 0 - 255
[avgduration-rtd <(0 to
255 StepSize 1)> ]
The default RTD average
duration for triggers, in
milliseconds
Optional 50 0 - 255
Command
Modes
bs configuration mode