User Manual

Chapter 4 - Operation and Administration Using the CLI Managing BSs
4Motion 591 System Manual
4.8.10 Managing Trigger Setup Parameters
After enabling the BS configuration mode, you can execute the following tasks:
Configure one or more of the Trigger Setup parameters (refer to
Section 4.8.10.1).
Restore the default values of one or all of the Trigger Setup parameters (refer to
Section 4.8.10.2).
You can display configuration information for the Trigger Setup parameters of a
selected or all existing BSs (refer to Section 4.8.10.3).
4.8.10.1 Configuring Trigger Setup Parameters
From the BS configuration mode, run the following command:
npu(config-bs-66053)# triggersetup [hysteresismargin <(0 to 255 StepSize 1)>]
[timetotrigger <(0 to 255 StepSize 1)>] [avgduration-rssi <(0 to 255 StepSize 1)>]
[avgduration-cinr <(0 to 255 StepSize 1)>] [avgduration-rtd <(0 to 255 StepSize
1)>]
Display
Format
(for a
selected
Trigger)
BSIDLSB :<value>
scnReqRssiMin :<value>
Command
Modes
Global command mode
To configure the Trigger Setup Parameters:
IMPORTANT
When creating a new BS, at least one of the Trigger Setup parameters must be configured explicitly
(even if configured to the default value).