User Manual

Chapter 4 - Operation and Administration Using the CLI Managing BSs
4Motion 585 System Manual
4.8.8.2 Restoring the Default Values of Neighbor Advertisement
Parameters
To restore one or all of the Neighbor Advertisement parameters to their default
values, run the following command:
npu(config-bs-66053)# no nbradvertise [mininterval-normalload]
[mininterval-highload] [triggersetup]
You can restore only some parameters to their default values by specifying only
those parameters. For example, to restore only the mininterval-normalload
parameters to the default values, run the following command:
npu(config-bs-66053)# no nbradvertise mininterval-normalload
This parameter will be restored to its default value, while the other parameters
will remain unchanged.
To restore all Neighbor Advertisement parameters to their default value, run the
following command:
npu(config-bs-66053)# no nbradvertise
[mininterval-normalload
<(0 to 100 StepSize
0.1)> ]
The minimum interval (in
seconds) between
NBRADV transmissions in
normal load state.
Optional 0.5 0 -100 in
steps of 0.1
[mininterval-highload
<(0 to 100 StepSize
0.1)> ]
The minimum interval (in
seconds) between
NBRADV transmissions in
high load state.
Optional 4 0 -100 in
steps of 0.1
[triggersetup <(0 to 100
StepSize 0.1)> ]
The periodic NBRADV
transmission interval, in
seconds
Optional 10 0 - 100 in
steps of 0.1
Command
Modes
bs configuration mode
NOTE
Refer to Section 4.8.8.1 for a description and default values of these parameters.
Command
Syntax
npu(config-bs-66053)# no nbradvertise [mininterval-normalload]
[mininterval-highload] [triggersetup]