User Manual

Chapter 4 - Operation and Administration Using the CLI Managing BSs
4Motion 584 System Manual
4.8.8 Managing Neighbor Advertisement
Parameters
After enabling the BS configuration mode, you can execute the following tasks:
Configure one or more of the Neighbor Advertisement parameters (refer to
Section 4.8.8.1).
Restore the default values of one or all of the Neighbor Advertisement
parameters (refer to Section 4.8.8.2).
You can display configuration information for the Neighbor Advertisement
parameters of a selected or all existing BSs (refer to Section 4.8.8.3).
4.8.8.1 Configuring Neighbor Advertisement Parameters
From the BS configuration mode, run the following command:
npu(config-bs-66053)# nbradvertise [mininterval-normalload <(0 to 100
StepSize 0.1)>] [mininterval-highload <(0 to 100 StepSize 0.1)>] [triggersetup <(0
to 100 StepSize 0.1)>]
To configure the Neighbor Advertisement Parameters:
IMPORTANT
When creating a new BS, at least one of the Neighbour Advertisement parameters must be
configured explicitly (even if configured to the default value).
Command
Syntax
npu(config-bs-66053)# nbradvertise [mininterval-normalload <(0 to
100 StepSize 0.1)> ] [mininterval-highload <(0 to 100 StepSize
0.1)> ] [triggersetup <(0 to 100 StepSize 0.1)> ]
Privilege
Level
10
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values