4.8.7.2 Restoring the Default Values of Feedback Allocation
Parameters
To restore one or all of the Feedback Allocation non-mandatory parameters to
their default values, run the following command:
npu(config-bs-66053)# no feedbackalloc [pr-cdma] [ir-cdma] [ert-poll-enable]
You can restore only some parameters to their default values by specifying only
those parameters. For example, to restore only the pr-cdma and ir-cdma
parameters to the default values, run the following command:
npu(config-bs-66053)# no feedbackalloc pr-cdma ir-cdma
These parameters will be restored to their default value, while the other
parameters will remain unchanged.
To restore all Feedback Allocation non-mandatory parameters to their default
value, run the following command:
npu(config-bs-66053)# no feedbackalloc
4.8.7.3 Displaying Configuration Information for Feedback
Allocation Parameters
To display configuration information for Feedback Allocation parameters, run the
following command:
npu# show feedbackalloc bs [<(1 to 16777215 StepSize 1)
NOTE
Refer to Section 4.8.7.1 for a description and default values of these parameters.
Command
Syntax
npu(config-bs-66053)# no feedbackalloc [pr-cdma ] [ir-cdma ]
[ert-poll-enable]
Privilege
Level
10
Command
Modes
bs configuration mode