User Manual

Chapter 4 - Operation and Administration Using the CLI Managing BSs
4Motion 739 System Manual
4.8.28.3.4 Restoring the Default Values of Initial Ranging Parameters
To restore one or all of the Initial Ranging parameters to their default values, run
the following command:
npu(config-bs-66053-ranging)# no initrng [codes] [init-backoff-window-size]
[final-backoff-window-size]
You can restore only some parameters to their default values by specifying only
those parameters. For example, to restore only the codes parameter to the default
value, run the following command:
npu(config-bs-66053-ranging)# no initrng codes
The parameter will be restored to its default value, while the other parameters will
remain unchanged.
To restore all Initial Ranging parameters to their default value, run the following
command:
npu(config-bs-66053-ranging)# no initrng
4.8.28.3.5 Restoring the Default Values of Periodic Ranging Parameters
To restore one or all of the Periodic Ranging parameters to their default values,
run the following command:
Privilege
Level
10
Command
Modes
bs ranging configuration mode
NOTE
Refer to Section 4.8.28.2.4 for a description and default values of these parameters.
Command
Syntax
npu(config-bs-66053-ranging)# no initrng [codes ]
[init-backoff-window-size ] [final-backoff-window-size ]
Privilege
Level
10
Command
Modes
bs ranging configuration mode