User Manual
Chapter 4 - Operation and Administration Using the CLI Managing BSs
4Motion 723 System Manual
npu(config-bs-66053)# no mngmnt-alrmthrshld [retransmit-rate] [drop-rate]
You can restore only one parameter to the default value by specifying only that
parameter. For example, to restore only the drop-rate parameter to the default
value, run the following command:
npu(config-bs-66053)# no mngmnt-alrmthrshld drop-rate
This parameter will be restored to its default value, while the other parameter will
remain unchanged.
To restore all Management Alarm Thresholds parameters to their default value,
run the following command:
npu(config-bs-66053)# no mngmnt-alrmthrshld
4.8.26.3 Displaying Configuration Information for Management
Alarm Thresholds Parameters
To display configuration information of Management Alarm Thresholds
parameters, run the following command:
npu# show mngmnt-alrmthrshld bs [<(1 to 16777215 StepSize 1)
Specify the BS ID if you want to display information for a particular BS. For
example, to display the Management Alarm Thresholds parameters of BS 66053,
run the following command:
npu# show mngmnt-alrmthrshld bs 66053
Do not specify this parameter if you want to view information for all existing BSs.
To display information for all BSs, run the following command:
NOTE
Refer to Section 4.8.26.1 for a description and default values of these parameters.
Command
Syntax
npu(config-bs-66053)# no mngmnt-alrmthrshld [retransmit-rate ]
[drop-rate ]
Privilege
Level
10
Command
Modes
bs configuration mode