User Manual
Chapter 4 - Operation and Administration Using the CLI Managing BSs
4Motion 702 System Manual
4.8.23.2 Restoring the Default Values of Handover Control
Parametes
To restore the default values of some or all of the Handover Control parameters,
run the following command:
npu(config-bs-66053)# no hoctrl [enable-teksharing] [rtxtimer]
You can restore only one parameter to the default values by specifying only that
parameter. For example, to restore only the rtxtimer parameter to the default
value, run the following command:
npu(config-bs-66053)# no hoctrl rtxtimer
This parameter will be restored to its default value, while the other parameter will
remain unchanged.
To restore all Handover Control parameters to their default value, run the
following command:
npu(config-bs-66053)# no hoctrl
4.8.23.3 Displaying Configuration and Status Information for
Handover Control Parameters
To display configuration and status information of Handover Control parameters,
run the following command:
npu# show hoctrl bs [<(1 to 16777215 StepSize 1)
NOTE
Refer to Section 4.8.23.1 for a description and default values of these parameters.
Command
Syntax
npu(config-bs-66053)# no hoctrl [enable-teksharing ] [rtxtimer ]
Privilege
Level
10
Command
Modes
bs configuration mode