User's Manual

Table Of Contents
140 Operation
Chapter 4 - Operation and Administration
If the specified file already exists as the Shadow version (meaning that
previously a Download operation was executed for this SW File), the only
actual operation to take place will be to reset and run from Shadow. If the
specified file already exists as the Main version, no action will take place.
Set as Main: Select this option to download the SW File from the NPU to the
Shadow memory of the AU, reset the AU and reboot using the Shadow version,
and then swap the Main and Shadow SW Version, so that the running version
(which was previously the Shadow version) will become the Main version, to be
used after next reset.
If the specified file already exists as the running version and it is defined as the
Shadow version (meaning that previously a Download and Run from Shadow
operation was executed for this SW File), the only actual operation to take
place will be to swap the Main and Shadow versions. If it is already defined as
the Main version, no action will take place.
4.8.5.2.3.3 SU SW File
Select this option to define the Name of the SW File to be used for upgrading the
SUs served by this AU after network entry, and the Action to be taken with this
file. Not applicable for any Permanent SU whose Configured SW File Name is other
than None (see Section 4.9.7.2.4.2) The SU SW File parameters are:
4.8.5.2.3.3.1Name
The Name of the SW File to be used for upgrading the SUs served by this AU.
Should be one of the AU SW Files currently stored in the NPU, or None (null).
4.8.5.2.3.3.2Action
The operation to be performed with the SU SW File: None (do not load), Load (load
to Shadow), Run from Shadow or Set as Main. Refer to Section 4.9.7.2.4.2.2 for
more details on these Actions.
4.8.5.2.3.4 Clear All Configured SU SW Files for this AU
Select this option to clear (delete) the SU Configured SW File in all Permanent SUs
served by this AU.
4.8.5.3 Configuration
The AU Configuration menu enables viewing and updating the AU's parameters. It
is important to note that changes to some parameters take effect only after reset.
For these parameters, the applicable Show menus display the Current as well as
the Configured value.