User's Manual

Table Of Contents
AU Menu
BreezeMAX Modular Base Station System Manual 139
4.8.5.2.3.1 Show Versions
Select this option to view the following information:
Versions in AU:
Main SW File Name
Main SW Version
Shadow SW File Name
Shadow SW Version
Running From: Main or Shadow
Available Versions in NPU: The available AU SW file names and the SW version
of each file.
4.8.5.2.3.2 SW File
Select this option to define the Name of the SW File to be used for upgrading the
AU after installation as well as after each reset, and the Action to be taken with
this file:
4.8.5.2.3.2.1Name
The Name of the SW File to be used for upgrading the AU after installation as well
as after each reset. Should be one of the AU SW Files currently stored in the NPU,
or None (null).
4.8.5.2.3.2.2Action
The operation to be performed with the SW File when the AU is installed, as well
as after each reset: None (do not load), Load (load to Shadow), Run from Shadow
or Set as Main:
None: Select None to cancel a pending request for another operation (an
operation will be executed only after the next reset).
Download: Select this option to download the specified SW File to the Shadow
memory of the AU. If the file already exists in the AU, no action will take place.
Run from Shadow: Select this option to download the specified SW File from
the NPU to the Shadow memory of the AU, reset the AU and reboot using the
Shadow version. Note that because the process is controlled by the NPU, the
AU will continue running from the Shadow version after reset.