User's Manual

Table Of Contents
Completing the Software Upgrade (Switching Versions)
BreezeMAX Modular Base Station System Manual 235
A.3 Completing the Software Upgrade
(Switching Versions)
After verifying successful upload of all software files, set the new version as the
main version in each one of the upgraded system elements:
SU(s): Select the SU that should be upgraded. Select Unit Control > SW
Versions Control > Set as Main, and enter the name of the new SU SW file. The
unit will reset automatically and will use the new version after power-up.
Repeat the process for all SUs that should be upgraded.
AU(s): Select the AU that should be upgraded. Select Unit Control > SW
Versions Control > Set as Main, and enter the name of the new AU SW file. The
unit will reset automatically. After power-up, the unit will use the new version.
Repeat the process for all AUs that should be upgraded.
NPU/μBST: Select Unit Control > SW Versions Control > Run from Shadow. The
system will reset automatically. After power-up, the NPU/μBST will run from
the new version, that at this stage is still marked as the Shadow Version. To
switch versions, select Unit Control > SW Versions Control > Set as Main.