User's Manual

Table Of Contents
216 Operation
Chapter 4 - Operation and Administration
4.11 NPU Parameters Summary
Table 4-23: NPU Monitor Parameters Summary
Parameter Range Default Run-Time
Updated
Base Station Configuration Parameters
Device Name Up to 255 printable characters Null Yes
Device Location Up to 255 printable characters Null Yes
ATPC Enable/Disable 1 - Disable
2 - Enable
Disable is temporary until next reset of the
AUs
Enable Yes
Optimal Uplink RSSI (dBm) -103 to -50 -69 Yes
Operator ID X.X.X
X: 0-255
186.190.0 No
Cell ID X.X
X: 0-255
0.250 No
Duplex Mode FDD, TDD TDD No
DL-UL Ratio 1: 65-35
2: 60-40
3: 55-45
4: 50-50
5: 45-55
6: 40-60
7: 35-65
65-35 No
External 1PPS Clock 1 - Disable
2 - Enable
Enable No
External 16MHz Clock 1 - Disable
2 - Enable
Disable No