138 Operation
Chapter 4 - Operation and Administration
Active Voice Calls
4.8.5.2 Unit Control
The AU Unit Control menu enables resetting the AU and managing the SW
versions of the module.
The Unit Control menu includes the following options:
Reset
Set Factory Defaults
SW Version Control
4.8.5.2.1 Reset Unit
Select this option to reset the unit. To avoid unintentional reset, you will be
prompted to confirm the reset request. Changes to some of the configurable
parameters are applied only after reset. Refer to Section 4.11 for information on
which parameters are changeable in run time and which changes are applied only
after reset.
4.8.5.2.2 Set Factory Defaults
Select this option to set the AU parameters to their factory default values. Refer to
Section 4.11 for information on the factory default values of these parameters.
The parameters will revert to their default values after the next reset.
4.8.5.2.3 SW Versions Control
The AU can contain two SW versions:
Main: Each time the AU resets it will reboot using the version defined as Main.
Shadow: Normally, the Shadow version is the backup version. Each time a new
SW File is downloaded to the AU, it will be stored as a Shadow version,
replacing the previous Shadow Version.
The process of upgrading to a new SW version is controlled by the NPU, and is
performed using one of the AU SW files installed in the NPU. If the specified AU
SW file does not exist in the AU, it will be downloaded to the AU and the requested
operation will be executed, as described below. If it already exists in the AU, then
actual loading is not necessary.
The following options are available in the SW Version Control menu: