User's Manual

Chapter 3 - Operation and Administration Using the CLI Managing ODUs
4Motion 437 System Manual
2 You can now execute any of the following tasks:
» Configure one or more of the ODU Port parameters (refer to
Section 3.6.2.2)
» Restore the default value of the txpower-onoff parameter (refer to
Section 3.6.2.3)
3 Terminate the ODU Port configuration mode (refer to Section 3.6.2.4)
In addition, you can, at any time, display configuration and status information for
each or all of the ODU Ports (refer to Section 3.6.2.6) or delete an existing ODU
Port (refer to Section 3.6.2.5).
3.6.2.1 Enabling the ODU Port Configuration Mode\Creating an
ODU Port
To configure the parameters of an ODU Port, first enable the ODU Port
configuration mode for the specific ODU Port. Run the following command to
enable the ODU Port configuration mode for an existing ODU Port:
npu (config)# odu-port <(1 to 28 StepSize 1)> <(1 to 4 StepSize 1)>
To create a new ODU Port, the mandatory txpower parameter must be specified.
Run the following command to create a new ODU Port and enable the
configuration mode for this ODU Port:
npu (config)# odu-port <(1 to 28 StepSize 1)> <(1 to 4 StepSize 1)> txpower
<(0 to 46 StepSize 0.1)>
A new ODU Port is created with default values for the txpower-onoff parameter.
For example, to create Port 1 in ODU 1 with a configured Tx Power of 34 dBm, and
enable the parameters configuration mode for this ODU Port run the following
command:
npu (config)# odu-port 1 1 txpower 34
After enabling the configuration mode for an ODU Port you can execute any of the
following tasks:
Configure one or more of the parameters of the ODU Port (refer to
Section 3.6.2.2)
Restore the default value of the txpower-onoff parameter (refer to
Section 3.6.2.3)