User's Manual
Chapter 3 - Operation and Administration Using the CLI Managing ODUs
4Motion 431 System Manual
After enabling the parameters configuration mode for an ODU you can execute
any of the following tasks:
Configure one or more of the parameters tables of the ODU (refer to
Section 3.6.1.2)
Restore the default values of parameters in one or more of the parameters
tables of the ODU (refer to Section 3.6.1.3)
After executing the above tasks, you can terminate the ODU parameters
configuration mode (refer to Section 3.6.1.4) and return to the global
configuration mode.
ODU Type = oDUAAAABBBBZZZWPPRbyTCS, where:
AAAA = Lower bound of frequency band in MHz, rounded up to the nearest integer.
BBBB = Upper bound of frequency band in MHz, rounded down.
ZZZ = 000 in TDD systems.
W = N in TDD systems.
PP = maximum transmit power in dBm, rounded down.
R = number of receive channels.
T = number of transmit channels.
Command
Syntax
npu (config)# odu-params <(1 to 28 StepSize 1)> [required-odu-type {<a list of ODU types>}
Privilege
Level
10
Syntax
Description
Parameter Description Presence Default
Value
Possible Values
<(1 to 28
StepSize 1)>
The ODU
number
Mandatory N/A 1-28
required-odu-type
{<a list of ODU
types>}
The required
ODU type
(see details
below).
Mandatory
for a new
ODU object
N/A Any of the listed ODU types. See
details below.
Command
Modes
Global configuration mode