User's Manual

Chapter 3 - Operation and Administration Using the CLI NPU Configuration
4Motion 404 System Manual
25-pin micro D-Type ALRM-IN/OUT connector corresponding to the alarm
number you are configuring:
In this table, N.C denotes Normally Closed, and N.O denotes Normally Open.
Refer Figure 3-3
for a diagrammatic representation of the 25-pin micro D-Type
ALRM-IN/OUT connector and the numbers assigned to each pin.
Table 3-29: Pin Numbers Corresponding to Dry Contact Output Alarm Numbers
Pin Number Corresponding Alarm Number
1(FIX) - 2(N.C) - 14(N.O) 1
11(FIX)- 12(N.C) - 13(N.O) 2
23(FIX) - 24(N.C) - 25(N.O) 3
NOTE
After you have raised an alarm, clear this alarm when the system state returns to its normal
condition. For information, refer to,
“Clearing Dry-contact Output Alarms” on page 405.
For more information about displaying configuration information about a dry contact output alarm,
refer to
“Displaying Configuration Information for Dry-contact Input/Output
Alarms” on page 406
.
Command
Syntax
npu(config)# dry-contact OUT <alarm_num (1-3)> alarm <alarm name >
Privilege
Level
10
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
<alarm_num
(1-3)>
Indicates the alarm number of
the dry contact output alarm
that is to be configured. This
alarm number corresponds to
a pin on the 25-pin micro
D-Type jack .
For more information about
pin numbers that correspond
to the alarm number, refer
Table 3-29.
Mandatory N/A 1-3