User's Manual
Chapter 3 - Operation and Administration Using the CLI NPU Configuration
4Motion 401 System Manual
Syntax
Description
Parameter Description Presence Default
Value
Possible Values
<alarm_num
(1-8)>
Indicates the alarm
number of the dry
contact input alarm
that is to be mapped
to an alarm condition.
This alarm number
corresponds to a pin
on the 25-pin micro
D-Type jack .
For more information
about the pin numbers
that correspond to the
alarm number, refer
Table 3-28.
Mandatory N/A 1-8
alarm
{CommercialPow
erFailure |
Fire |
EnclosueDoorOp
en |
HighTemperatur
e | Flood |
LowFuel |
LowBatteryThre
shold |
GeneratorFailu
re |
IntrusionDetec
tion |
ExternalEquipm
entFailure
Indicates the alarm
condition to be
mapped to a pin
number.
Mandatory N/A
CommercialPowerFai
lure
Fire
EnclosueDoorOpen
HighTemperature
Flood
LowFuel
LowBatteryThreshold
GeneratorFailure
IntrusionDetection
External
ExternalEquipmentFa
ilure (can be used
for defining a
condition other than
the ones specified
by the other
parameters in this
command)
[alarmPolarity
{RaiseOnClose
| RaiseOnOpen
}]
Indicates whether
alarm will be raised on
closed or open circuit
condition.
Optional RaiseOn
Close
RaiseOnClose
RaiseOnOpen