User's Manual

Chapter 3 - Operation and Administration Using the CLI Managing BSs
4Motion 622 System Manual
Configure one or more of the Alarm Threshold parameters (refer to
Section 3.8.24.1).
Restore the default values of some or all of the Alarm Threshold parameters
(refer to Section 3.8.24.2).
You can display configuration and status information for the Alarm Threshold
parameters of a selected or all existing BSs (refer to Section 3.8.24.3).
3.8.24.1 Configuring Alarm Threshold Parameters
From the BS configuration mode, run the following command:
npu(config-bs-66053)# alrm-thrshld [ul-mednoise <(-135 to -100 StepSize 1)>]
[ul-99prcntnoise <(-135 to -100 StepSize 1)>] [Be-exc-dl-drop-thr <(1 to 1000
StepSize 1)> ] [rt-exc-dl-drop-thr <(1 to 1000 StepSize 1)> ] [nrt-exc-dl-drop-thr
<(1 to 1000 StepSize 1)> ] [ugs-exc-dl-drop-thr <(1 to 1000 StepSize 1)> ]
[ert-exc-dl-drop-thr <(1 to 1000 StepSize 1)> ]
To configure the Alarm Threshold parameters:
Command
Syntax
npu(config-bs-66053)# alrm-thrshld [ul-mednoise <(-135 to -100
StepSize 1)> ] [ul-99prcntnoise <(-135 to -100 StepSize 1)> ]
[Be-exc-dl-drop-thr <(1 to 1000 StepSize 1)> ] [rt-exc-dl-drop-thr
<(1 to 1000 StepSize 1)> ] [nrt-exc-dl-drop-thr <(1 to 1000
StepSize 1)> ] [ugs-exc-dl-drop-thr <(1 to 1000 StepSize 1)> ]
[ert-exc-dl-drop-thr <(1 to 1000 StepSize 1)> ]
Privilege
Level
10
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values