User's Manual

Chapter 3 - Operation and Administration Using the CLI Managing BSs
4Motion 500 System Manual
npu# show pwrctrl-nilevels bs
3.8.6.5.2 Displaying Configuration Information for Power Control Maximum
EIRxP
The Maximum EIRxP parameter defines the maximum effective isotropic received
power at the BS for Initial ranging..
In the current release this parameter cannot be configured and is set by the value
in the vendor parameters file.
Command
Syntax
npu# show pwrctrl-nilevels bs [<(1 to 16777215 StepSize 1)
Privilege
Level
1
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
<(1 to 16777215
StepSize 1)>
The BS ID
Specify a value for this
parameter if you want to
display the Target Noise and
Interference Level
parameters of a specific BS.
Do not specify a value for this
parameter if you want to
display the Target Noise and
Interference Level
parameters of all BSs.
Optional N/A 1-16777215
Display
Format
(for each
existing BS
if requested
for all BSs)
BSIDLSB :<value>
NoiseandInterferenceLevelforCQI&ACKRegion :<value>
NoiseandInterferenceLevelforPUSCZone :<value>
PowerControlCorrectionFactor :<value>
Command
Modes
Global command mode