User's Manual
Chapter 3 - Operation and Administration Using the CLI Managing BSs
4Motion 492 System Manual
Restore the default values of parameters in one or more of the parameters
tables (refer to Section 3.8.6.3)
After executing the above tasks, you can terminate the Power Control
configuration mode (refer to Section 3.8.6.4) and return to the BS configuration
mode.
3.8.6.2 Configuring Power Control Parameters
After enabling the Power Control configuration mode you can configure the
following parameters tables:
Target Noise and Interference Level (refer to Section 3.8.6.2.1)
Required C/N Level (refer to Section 3.8.6.2.2)
3.8.6.2.1 Configuring Power Control Target Noise and Interference Level
Parameters
The Target Noise and Interference Level table enables defining the target limits for
various noise and interference levels.
To configure the Target Noise and Interference Levels, run the following command:
npu(config-bs-66053-pwrctrl)# nilevels [cqi-ack-ranging <(-150 to -22.5
StepSize 0.5)>] [pusc <(-130 to -110 StepSize 0.5)>]
[power-control-correction-factor <(-20 to 30 StepSize 0.1)>]
Command
Syntax
npu(config-bs-66053)# pwrctrl
Privilege
Level
10
Command
Modes
bs configuration mode
NOTE
In the current release, the command for configuring Maximum EIRxP parameter,
npu(config-bs-66053-pwrctrl)# maxeirxp, is not applicable and should not be used. An attempt to
configure a value using this command will be ignored (value is taken from vendor file).