User's Manual
Chapter 2 - Commissioning Initial NPU Configuration
4Motion 57 System Manual
for UDP and TCP ports 161 and 162 from Outside IP (connected to the managed
device’s LAN) to Inside IP (connected to the management system’s LAN).
2.1.6 Mapping the AU Software Version
To define the software version to be used by all AUs run the command:
npu(config)# map au default <image name>, where image name is the required AU
software version (to view the AU software versions available in the NPU run the
command npu# show au image repository).
2.1.7 Site ID Definition
To define the site ID (Site Number): npu(config)# site identifier x
(x is the unique site identifier, a number in the range from 1 to 999999)
For more details refer to “Configuring the Unique Identifier for the 4Motion Shelf”
on page 410.
2.1.8 Saving the Configuration
To save the configuration run the command: npu# write (otherwise, after the next
time reset you will lose the configuration changes).