User's Manual
Chapter 2 - Commissioning Initial NPU Configuration
4Motion 54 System Manual
2.1 Initial NPU Configuration
2.1.1 Introduction
After completing the installation process, as described in the preceding chapter,
some basic NPU parameters must be configured locally using the CLI via the MON
port of the NPU.
Refer to “Using the Command Line Interface for Management” on page 68 for
information on how to access the CLI either via the MON port or via Telnet and
how to use it.
The following sections describe the minimum mandatory configuration actions
required to allow remote configuration of the site and to enable discovery by the
EMS system:
1 ”NPU Local Connectivity”
2 ”Site Connectivity”
3 ”Static Route Definition”
4 ”SNMP Manager Definition”
5 ”Mapping the AU Software Version”
6 ”Site ID Definition”
7 ”Saving the Configuration”
2.1.2 NPU Local Connectivity
Refer to “Accessing the CLI from a Local Terminal” on page 70 for details on
connecting locally to the NPU.
Clear existing site configuration (must be executed for "used” NPUs). Restore to
factory default and reboot using the following command:
npu# restore-factory-default
The system will reset automatically.
2.1.3 Site Connectivity
2.1.3.1 Connectivity Mode
The connectivity mode determines how traffic is to be routed between the NPU and
the BSs, AAA server and external Management System servers.