User's Manual

Chapter 3 - Operation and Administration Using the CLI NPU Configuration
4Motion 117 System Manual
3.3.2.2 Managing the External Ether Type
The External Ether Type parameter defines the EtherType in outer VLAN header of
uplink Q-in-Q traffic. The External Ether Type parameter is not applicable the
device operates in Transparent (Centralized ASN Topology) mode.
This section includes:
“Configuring the External Ether type”
“Displaying the Ether Type”
3.3.2.2.1 Configuring the External Ether type
To configure the Ether Type run the following command:
npu(config)# config npuEtherType {8100 | 88A8 | 9100 | 9200}
Command
Syntax
npu# show interface gigabitethernet <interface-id> vlan mapping
Privilege
Level
1
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
<interface-id> Indicates the identifier of the
Gigabit Ethernet interface for
which VLAN translation
entries are to be displayed.
In current release VLAN
Mapping is supported only on
the DATA port (interface-id
0/10).
Mandatory N/A
0/10
Command
Modes
Global command mode
Command
Syntax
npu(config)# config npuEtherType {8100 | 88A8 | 9100 | 9200}