Chapter 3 - Operation and Administration Using the CLI Using the Command Line Interface for Management
4Motion 69 System Manual
“Managing Users and Privileges” on page 78
“Managing Secure Shell (SSH) Parameters” on page 87
“Managing the Session” on page 89
3.1.1 Managing the Macro Outdoor BTS
The following section describe the CLI when using it to manage the Indoor Macro
BTS equipment. The same CLI is used also to manage the Macro Outdoor BTS
equipment, with the following changes:
3.1.1.1 CSCD Port and Local Management
There is no CSCD port in the Macro Outdoor BTS. Local Management may be
supported only on the Management port (in in-band or unified connectivity mode).
It should be noted that local management will be blocked if connectivity mode is
set to out-of-band.
3.1.1.2 Management Port
In the Macro Outdoor BTS the management port is marked MNG, while in the
Indoor BTS it is marked MGMT. All references to MGMT port are applicable to the
MNG port of the Macro Outdoor BTS.
3.1.1.3 AVU, PIU and PSU
AVU and its Fans, PIUs and PSUs do not exist in the Macro Outdoor BTS. These
shelf components cannot be manage and the status of all the following is
indicated as existing and healthy:
2 PIUs
4 PSUs
AVU
10 AVU Fans
3.1.1.4 Alarm In/Out Connectors and Dry-Contacts Management
Alarm In-Out connectors do not exist in the Macro Outdoor BTS. All commands
related to dry-contact in/out are not applicable.