User's Manual
Chapter 3 - Operation and Administration Using the CLI NPU Configuration
4Motion 215 System Manual
The following table provides some details on these parameters:
Display
Format
Data Path Function Configuration :
dpTimerInitPathRegReq <value>
dpCounterInitPathRegReqMax <value>
dpTimerMsDeregReq <value>
dpCounterMsDeregReqMax <value>
dpTimerPathRegReq <value>
dpCounterPathRegReqMax <value>
dpTimerPathRegRsp <value>
dpCounterPathRegRspMax <value>
dpTimerPathRegStart <value>
dpTimerMipWaitDhcp <value>
Command
Modes
Global command mode
Parameter Description
dpTimerInitPathRegReq The interval, in milliseconds, after which the request for initial path
registration should be complete. If the initial path registration request is not
completed within this period, the NPU may retransmit the initial path
registration request.
dpCounterInitPathRegReqMax The maximum number of initial path registration request retransmissions
that may be sent by the NPU. After the number of retransmissions has
exceeded the value of this parameter, the MS de-registration procedure is
initiated.
dpTimerMsDeregReq The MS deregistration response timeout, in milliseconds.
dpCounterMsDeregReqMax The maximum number of MS deregistration request retransmissions, after
which the MS is de-registered.
dpTimerPathRegReq The period, in milliseconds, with which the NPU should wait for the path
registration response. If a response is not received within this period, the
NPU retransmits the request.
dpCounterPathRegReqMax The maximum number of times the NPU may retransmit the path
registration request.