User's Manual

Chapter 3 - Operation and Administration Using the CLI NPU Configuration
4Motion 214 System Manual
3.3.11.7 Managing the Data Path Function
The Data Path function controls the creation, maintenance, and deletion of data
paths within the NPU. Data Path function parameters can be configured only by
the vendor.
To display configuration information for the Data Path function, run the following
command:
npu# show datapath
eapCounterReAuthAttemptMax The maximum number of times the NPU may handle a an
MS/network-initiated re-authentication request. When the number of
re-authentication attempts exceeds the value of this parameter, the MS is
de-registered.
authTimerReauthCmpltHold The period, in milliseconds, within which, re-authentication of the MS
should be complete. If the MS is not authenticated within this period, the
NPU reinitiates MS authentication.
eapCounterRndTripsMax The number EAP roundtrips in one authentication/re-authentication
process.
authTimerPmkLifetime The period, in seconds, for which the MS authentication key is valid. At the
end of this period, the NPU de-registers the MS.
authTimerPmkGaurd The duration of the guard timer for the MS authentication keys. the NPU
initiates re-authentication for the MS after the pmk guard timer has
expired. (The value of this timer is pmk-lifetime - pmk-guardtime.)
If the value of this parameter is 0, the guard timer is not started.
authTimerAuthFailureHold The period, in seconds, for which the MS context is retained after
authentication failure.
authCounterNtwEntryMax The maximum number of times that the NPU may handle a network entry
request from an MS, after prior attempts for that MS has already failed.
After the NPU has handled max-ntwentry number of attempts and its
value is 0, the MS is assigned the unauthenticated mode.
Command
Syntax
npu# show datapath
Privilege
Level
1