User's Manual

Chapter 3 - Operation and Administration Using the CLI NPU Configuration
4Motion 290 System Manual
[uldatadlvry-t
ype
<type(0<UGS> |
1<RTVR> |
2<NRTVR> |
3<BE> |
4<ERTVR> |
255<ANY>)>]
Denotes the data delivery
type for uplink traffic carried
by the service flow.
Optional 3 (BE) 0-4 or 255 for
ANY.
[ulqos-maxsust
ainedrate
<value(10000-4
0000000)>]
Denotes the maximum
sustained traffic rate, in bps,
for uplink traffic carried by the
service flow.
Although available for all
service flows, applicable only
for service flows with the
appropriate uplink data
delivery type (NRTVR,
RTVR, BE, ERTVR, ANY)
Optional 250000 10000-400000
00 bps
[ulqos-traffic
priority
<value(0-7)>]
Denotes the traffic priority to
be applied to the uplink traffic
carried by the service flow.
Although available for all
service flows, not applicable
for service flows with UGS
uplink data delivery type.
Optional 0 0-7, where 0 is
lowest and 7 is
highest
[dldatadlvry-t
ype
<type(0<UGS> |
1<RTVR> |
2<NRTVR> |
3<BE> |
4<ERTVR> |
255<ANY>)>]
Denotes the data delivery
type for the downlink traffic
carried by the service flow.
Optional 3 (BE)
0 (UGS)
1 (RTVR)
2 (NRTVR)
3 (BE)
4 (ERTVR)
255 (ANY)
[dlqos-maxsust
ainedrate
<value(10000-4
0000000)>]
Denotes the maximum
sustained traffic rate, in bps,
for the downlink traffic carried
by the service flow.
Although available for all
service flows, applicable only
for service flows with the
appropriate downlink data
delivery type (NRTVR,
RTVR, BE, ERTVR, ANY)
Optional 250000 10000-400000
00 bps