User's Manual

Chapter 1 - System Description The Base Transceiver Station
4Motion 22 System Manual
1.3.4 Power Feeder
The PIU of the indoor Macro BTS can support a maximum current of 58 A (@-40.5
VDC). In certain installations with a relatively high number of ODUs this current
may not be sufficient to power the shelf and all the ODUs. In such installations
the ODU Power Feeder is used as an additional power source providing power (-48
VDC) to ODUs. It transfers transparently all signals between the AU and the ODU,
while injecting DC power received from an external source. Each ODU Power
Feeder unit can serve up to four ODUs. Up to three ODU Power Feeder units can
be installed in a 1U high Power Feeder panel.
1.3.5 Antenna
In the 4Motion architecture, the antenna is approached as an independent
element. This provides the operator with the flexibility to select the antennas
source according to its supplier policy. To ensure the availability of antennas that
2.5 2496-2602 (band A) 1Rx by 1Tx Up to 10 36
2590-2690 (band B) 1Rx by 1Tx Up to 10 36
2485-2690 2Rx by 2TX Up to 30 38 (37 in the
2485-2495
GHz band)
2496-2602 (band A) 4Rx by 2Tx Up to 20 38
2590-2690 (band B) 4Rx by 2Tx Up to 20 38
2485-2690 4Rx by 2Tx Up to 20 38 (37 in the
2485-2695
GHz band)
2560-2570 4Rx by 2Tx Up to 10 37
3.3 3300-3355 1Rx by 1 Tx Up to 14 32
3.5 3400-3455 1Rx by 1Tx Up to 14 34
3445-3500 1Rx by 1Tx Up to 14 34
3500-3555 1Rx by 1Tx Up to 14 34
3545-3600 1Rx by 1Tx Up to 14 34
3400-3600 2Rx by 2Tx Up to 30 37
3400-3600 4Rx by 2Tx Up to 20 37
3.6 3600-3800 4Rx by 2Tx Up to 20 36
Table 1-3: ODU Types
Band (GHz) ODU Frequency Range
(MHz)
ODU Port
Configuration
ODU Bandwidth
(MHz)
ODU Max Tx