User's Manual
Chapter 2 - Commissioning Completing the Site Configuration Using AlvariSTAR
4Motion 65 System Manual
4 At least one Site Sector Association must be defined for each Site Sector. Click
on the Add Sector Association button and configure all the parameters in the
applicable line of the Sector site Association table:
» BS ID LSB
» AU Slot Number
» AU Port Number
» ODU Number
» ODU Port Number
» Antenna Number
» Antenna Port Number
5 Click Apply for the device to accept the configuration.
2.2.8 Apply All Changes
If you changed any of the parameters that are applied only after reset of the NPU
such as ASN Topology or Configured GPS Type (indicated by a pop-up message
after applying the change), you must reset the NPU (in the NPU screen select the
Reset option in the Shutdown Operation parameter). This will cause also
automatic reset of all AUs
To fully apply all the Site Sector configuration changes, reset all the relevant AUs
(in the Control tab of each applicable AU screen select the Reset option in the
Shutdown Operation parameter). It is not necessary to reset each of the AUs if you
reset the NPU.