User's Manual
Chapter 3 - Operation and Administration Using the CLI Managing AUs
4Motion 418 System Manual
3.5.2.3 Configuring AU Connectivity
The connectivity tables enables configuring the connectivity parameters for the
Ethernet interface of the AU. In the current release the interface operates in
802.1q mode: In this mode, the interface accepts only VLAN-tagged packets. All
packets received without VLAN tags are dropped.
The connectivity tables enable also configuring the parameters of the service
interface (excluding the VLAN ID) used by the AU for uploading maintenance
information to an external server (the same VLAN ID is used by all service
interfaces - for details see Section 3.3.3).
To configure the connectivity parameters, run the following command:
npu(config-au-1)# connectivity [maxframesize <(1518 to 9000
StepSize 1)>] [bearervlanid <(9 to 9 StepSize 1) | (11 to 100
StepSize 1) |(110 to 4094 StepSize 1)>] [service-ip <ip address> ]
[service-mask <ip address> ] [service-next-hop <ip address> ]
Command
Syntax
npu(config-au-1)# control shutdown-operation {normalOperation |
reset | shutdown}
Privilege
Level
10
Syntax
Description
Parameter Description Presence Default
Value
Possible Values
shutdown-operation
{normalOperation |
reset | shutdown}
Controls the
operation of the AU
card: Normal
Operation, Shutdown
(disable power to
card) or Reset.
Mandatory normal
Operation
normalOperation
reset
shutdown
Command
Modes
au configuration mode