Chapter 3 - Operation and Administration Using the CLI NPU Configuration
4Motion 407 System Manual
3.3.15.7 Managing the Site General Information for the 4Motion Shelf
The site general parameters provide general information on the site.
This section describes the commands used for:
“Configuring the Site General Information for the 4Motion Shelf” on page 408
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
{IN|OUT} Indicates whether
configuration information is to
be displayed for input or
output alarms. If you do not
specify this value,
configuration information is
displayed for all input and
output alarms.
Optional N/A
IN
OUT
[<alarm_num>] Denotes the alarm number of
the input or output alarm for
which configuration
information is to be displayed.
Refer
Figure 3-2 and
Figure 3-3 for more
information about the
numbers assigned to the pins
used for connecting dry
contact alarms.
Optional N/A
1-8 for input
alarms
1-3 for
output
alarms
Display
Format
Dry-Contact Input Alarm:
AlarmNumber AlarmName InputBlocking AlarmPolarity
<alarm num> <alarm name> <Yes or No> Raise On Close/Open
Dry-Contact Output Alarm:
AlarmNumber AlarmStatus AlarmName
<alarm num> <On or Off> <name>
Command
Modes
Global command mode