User's Manual

Chapter 3 - Operation and Administration Using the CLI Managing Sectors
4Motion 652 System Manual
Creation of a new Sector Association entry will succeed only if all the following
conditions are met:
The specified BS object exists and is properly configured (see also Section 3.8):
» All mandatory parameters have been configured properly.
» The configured frequency is within the valid range defined by the required
ODU type in the specified ODU object and the bandwidth parameter.
» The Operator ID is the same as Operator ID configured for previously
associated BSs.
» In all tables that includes only non-mandatory parameters at least one
parameter has been configured.
» Wherever needed, the apply command has been executed.
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
<(1 to 16777215
StepSize 1)>
BS ID (bs-id-lsb) Mandatory N/A 1-16777215
<(1 to 4 StepSize 1) |
(7 to 9 StepSize 1)>
AU Slot ID Mandatory N/A 1-4, 7-9
<(1 to 4 StepSize 1)> AU Port Number Mandatory N/A 1-4
sector-id <(1 to 6
StepSize 1)>
Sector ID Mandatory N/A 1-6
odu-no <(1 to 28
StepSize 1)>
ODU Number Mandatory N/A 1-28
antenna-no <(1 to 28
StepSize 1)>
Antenna Number Mandatory N/A 1-28
odu-port-no <1 to 4
StepSize 1>
ODU Port Number Mandatory N/A 1-4
antenna-port-no <1 to
8 StepSize 1>
Antenna Port Number Mandatory N/A 1-4
Command
Modes
Global configuration mode