User's Manual

Chapter 3 - Operation and Administration Using the CLI Managing BSs
4Motion 533 System Manual
3.8.13.2.3 Configuring Trigger Setup Parameters
To configure the Neighbor BS Trigger Setup parameters, run the following
command:
npu(config-bs-66053-nbr-68000)# triggersetup [avgduration-rssi <(0 to 255
StepSize 1)>] [avgduration-cinr <(0 to 255 StepSize 1)>] [avgduration-rtd <(0 to
255 StepSize 1)>]
The configured values should be the same as those defined for the applicable
Trigger Setup parameters (see Section 3.8.10.3) in the neighbor BS.
3.8.13.2.4 Configuring Neighbor BS Triggers Parameters
To configure the Neighbor BS Triggers parameters, run the following command:
npu(config-bs-66053-nbr-68000)# triggers-<trigger-name> <trigger-range>
Each Trigger is configured separately. This is the general structure of the
command.
The configured trigger names and values should be the same as those defined for
the applicable Triggers parameters (see Section 3.8.9.2) in the neighbor BS.
Command
Syntax
npu(config-bs-66053-nbr-68000)# triggersetup [avgduration-rssi
<(0 to 255 StepSize 1)> ] [avgduration-cinr <(0 to 255 StepSize
1)> ] [avgduration-rtd <(0 to 255 StepSize 1)> ]
Privilege
Level
10
Syntax
Description
Refer to
Section 3.8.10.1
Command
Modes
bs neighbour bs configuration mode
IMPORTANT
When creating a new Neighbour BS, at least one of the Neighbour BS Trigges parameters must be
configured.