User's Manual

Table Of Contents
Menus and Parameters
4.2.3.3
The Change Unit Name option enables changing the name of the unit, which is
als used as the
prompt at the bottom of each Monitor window.
Valid values: A string of up to 32 printable ASCII characters.
4.2.3.4 Change Password
The sword(s). The
Ch enu is available only to users with Administrator access
rights.
Ref
Change Unit Name
o the system's name in the MIB2. The name of the unit is also
The default unit name is an empty string.
Change Password submenu enables changing the access pas
ange Password subm
Valid values: A string of up to 8 printable ASCII characters.
er to section 4.1
for a list of the default passwords for each of the access levels.
4.2.3.5 Flash Memory Control
ash Memory Control submenu enables selecting the active software version
and
select the shadow version as the new active version by selecting
after the next reset, the main
version is re-activated. To continue using the currently active version after the
w
red in the unit are not changed as a result of loading new
software versions unless the new version includes additional parameters or
the
Sel
Reset and Boot from Shadow Version: Activates the shadow (backup)
ally. Following the next reset the
unit will switch to the main version.
Use Running Version After Reset: Defines the current running version as
ed following the next reset.
The Fl
for the unit.
The flash memory can store two software versions. One version is called Main
the other is called Shadow. New software versions are loaded as the shadow
version. You can
Reset and Boot from Shadow Version. However,
next reset, select Use Running Version After Reset: The previous shado
version will be the new main version, and vice versa.
The parameters configu
additional changes in the list of parameters. New parameters are loaded with
ir default values.
ect from the following options:
software version. The unit is reset automatic
the new main version. This version will also be us
Operation and Administration
67