Operation Verification
3.4.2 Indoor Unit Verification
To verify the correct operation of the indoor equipment, examine the LE
indicators located on the top panel of the SU IDU and AU IDU units, or
front panel of the BS-AU module.
Table 3-6
D
on the
provides information for the BS-AU IDU LEDs. Table 3-7 lists
of the PS1073 IDU and their associated indications.
Table 3-6: BS-AU LEDs
the LEDs
Name Description Functionality
W-LINK Wireless link activity
Blinking Red - No SU is associated.
Off - Wireless link is disabled.
Green - At least one SU is associated.
ODU CURRENT
CONS
Current Consumption of
Red - over current.
d - open circuit or below
anticipated current consumption.
Green - within tolerance.
UMPTION the Outdoor Unit
Blinking Re
ODU STATUS Outdoor Unit Self-test
Green - Self test passed and ODU
ready for operation.
Blinking Amber - Testing (not ready
for operation)
Red - fatal failure.
IDU PWR Power indication for the
Indoor Unit
Green - IDU power is OK.
Off - no power is supplied to the IDU.
ALARM Indoor Unit Alarm
Indication
Red - a fatal failure indication.
Off - IDU is functioning properly.
Commissioning
51