User's Manual
Table Of Contents
- BreezeACCESS 4900 System Manual
- About This Manual
- Contents
- Figures
- Tables
- Chapter 1 - System Description
- Chapter 2 - Installation
- Chapter 3 - Commissioning
- Chapter 4 - Operation and Administration
- Working with the Monitor Program
- Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Advanced Configuration Menu
- IP Parameters
- Air Interface Parameters
- ESSID Parameters
- Frequency Definition Parameters
- Frequency Definition Submenu in AU
- Frequency Definition Submenu in SU
- Best AU Parameters (SU)
- Scanning Mode (SU only)
- Power Control Parameters
- Antenna Gain
- Cell Distance Parameters (AU only)
- Arbitration Inter-Frame Spacing (AIFS)
- Maximum Number of Associations (AU only)
- Wireless Link Trap Threshold (AU only)
- Spectrum Analysis
- Lost Beacons Transmission Watchdog Threshold
- Disassociate (AU only)
- Network Management Parameters
- Bridge Parameters
- VLAN Support
- Ethernet Broadcast Filtering (SU only)
- Ethernet Broadcast/Multicast Limiter
- Bridge Aging Time
- Broadcast Relaying (AU only)
- Unicast Relaying (AU only)
- MAC Address Deny List (AU only)
- Add MAC Address to Deny List
- Remove MAC Address from Deny List
- Roaming Option (SU only)
- Ports Control (SU only)
- Show Bridge Parameters
- Performance Parameters
- Service Parameters
- Security Parameters
- Appendix A - Software Version Loading Using TFTP
- Appendix B - File Download and Upload Using TFTP
- Appendix C - Using the Set Factory Defaults Utility
- Appendix D - Preparing the Indoor to Outdoor SU Cable
- Appendix E - Supported MIBS and Traps
- Appendix F - Parameters Summary
- Appendix G - Using the Feature License Web Application
- Appendix H - Troubleshooting
Chapter 2 - Installation
2.5 Installing the Modular Base Station
Equipment
The following sections describe the slot assignment for the Base Station chassis,
provide illustrated descriptions of the power supply modules and Access Unit
network interface modules, and describe how to install the Base Station
equipment.
2.5.1 BS-SH Slot Assignment
The Base Station chassis comprises ten slots, as shown in Figure 2-5.
Figure 2-5: BS-SH Chassis Slot Assignment
To enable power supply redundancy, two BS-PS power supply modules can be
ed i ide slots. If a single power supply module is used, it can be
inserted into either one of the two available slots.
The remaining eight slots can hold up to six BS-AU modules. Unused slots
should rem
sign s
Units with longing to BreezeACCESS VL family or other
rts any mixture of
CESS GFSK BS-AU
00
s and one BS-PS GFSK (AC or DC) for the BreezeACCESS GFSK
install n the wider s
ain covered until required.
The de of the BS-SH supports collocation of BreezeACCESS 4900 Acces
Access Units be
BreezeACCESS families using GFSK modulation. It suppo
BS-AU 4900 modules with BreezeACCESS VL or BreezeAC
modules, including an optional BS-GU-GPS module. If Access Units belonging to
BreezeACCESS GFSK families are used, then it is necessary to use two power
supply modules: one BS-PS (AC or DC) power supply for the BreezeACCESS 49
Access Unit
BreezeACCESS 4900 System Manual
34