User's Manual

Table Of Contents
Chapter 2 - Installation
Indoor-to-outdoor Category 5E Ethernet cable with shielded RJ-45 connectors
* (available in different lengths. For more details refer to section 2.1.2
)
Ethernet cable (straight for connecting to a hub/switch etc., crossed for
connecting directly to a PC’s NIC)
Crimping tool for RJ-45 connectors
Antenna, for E model units supplied without an antenna
Ground cables with an appropriate termination
Mains plug adapter or termination plug (if the power plug on the supplied AC
power cord does not fit local power outlets)
Portable PC with Ethernet card and Telnet software or BreezeCONFIG for
BreezeACCESS 4900* application and a crossed Ethernet cable
Installation tools and materials, including appropriate means (e.g. a pole) for
installing the outdoor unit.
NOTE
Items marked with an asterisk (*) are available from Alvarion.
2.1.2 Indoor-to-Outdoor Cables
NOTE
The length of the Ethernet cable connecting the indoor unit to the user's equipment, together with
the length of the Indoor-to-Outdoor cable, should not exceed 100 meters.
Use only Category 5E Ethernet cables from approved manufacturers, listed in
Table 2-1. Consult with Alvarion specialists on the suitability of other cables.
BreezeACCESS 4900 System Manual
24