User's Manual
Table Of Contents
- BreezeACCESS 4900 System Manual
- About This Manual
- Contents
- Figures
- Tables
- Chapter 1 - System Description
- Chapter 2 - Installation
- Chapter 3 - Commissioning
- Chapter 4 - Operation and Administration
- Working with the Monitor Program
- Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Advanced Configuration Menu
- IP Parameters
- Air Interface Parameters
- ESSID Parameters
- Frequency Definition Parameters
- Frequency Definition Submenu in AU
- Frequency Definition Submenu in SU
- Best AU Parameters (SU)
- Scanning Mode (SU only)
- Power Control Parameters
- Antenna Gain
- Cell Distance Parameters (AU only)
- Arbitration Inter-Frame Spacing (AIFS)
- Maximum Number of Associations (AU only)
- Wireless Link Trap Threshold (AU only)
- Spectrum Analysis
- Lost Beacons Transmission Watchdog Threshold
- Disassociate (AU only)
- Network Management Parameters
- Bridge Parameters
- VLAN Support
- Ethernet Broadcast Filtering (SU only)
- Ethernet Broadcast/Multicast Limiter
- Bridge Aging Time
- Broadcast Relaying (AU only)
- Unicast Relaying (AU only)
- MAC Address Deny List (AU only)
- Add MAC Address to Deny List
- Remove MAC Address from Deny List
- Roaming Option (SU only)
- Ports Control (SU only)
- Show Bridge Parameters
- Performance Parameters
- Service Parameters
- Security Parameters
- Appendix A - Software Version Loading Using TFTP
- Appendix B - File Download and Upload Using TFTP
- Appendix C - Using the Set Factory Defaults Utility
- Appendix D - Preparing the Indoor to Outdoor SU Cable
- Appendix E - Supported MIBS and Traps
- Appendix F - Parameters Summary
- Appendix G - Using the Feature License Web Application
- Appendix H - Troubleshooting
Appendix F - Parameters Summary
F.1 Unit Control Parameters
Parameter Unit Range Default Run-Time
Change Unit Name printable ASCII AU, SU Up to 32
characters
None Yes
Change Read Only table ASCII
Password
AU, SU Up to 8 prin
characters
public No
Change Installer AU, SU Up to 8 printable ASCII user No
Password characters
Change
Administrator
Password
AU, SU le ASCII private No Up to 8 printab
characters
FTP SW Version AU, SU le ASCII
characters. An empty string
VxWorks.bz Yes Up to 20 printab
File Name
is not allowed.
Configuration File
Name
AU, SU
g
onfig.cfg Yes Up to 20 printable ASCII
characters. An empty strin
c
is not allowed.
Operator Defaults
File Name
AU, SU
characters. An empty string
is not allowed.
operator.cmr Yes Up to 20 printable ASCII
FTP Source Dir AU, SU Up to 80 printable ASCII
characters. Use “.” to clear.
None (empty) Yes
FTP Client IP
Address
AU, SU IP address 1.1.1.3 No
FTP Client IP Mask AU, SU IP address 255.255.255.0 No
FTP Server IP
Address
AU, SU IP address 1.1.1.4 No
FTP Gateway IP
Address
AU, SU IP address 0.0.0.0 No
FTP User Name AU, SU Up to 18 printable ASCII
characters
vx No
FTP Password AU, SU Up to 18 printable ASCII
characters
Vx No
FTP Log File Name AU, SU Up to 20 printable ASCII
characters
logfile.log Yes
FTP Log File
Destination
Directory
AU, SU Up to 80 printable ASCII
characters. Use “.” to clear.
None (empty) Yes
Event Log Policy AU, SU
Message
Warning
Error
Fatal
Log None
Warning Yes
Log Out Timer AU, SU 1-999 minutes 5 Yes
BreezeACCESS 4900 System Manual
214