User's Manual

Table Of Contents
Chapter 4 - Operation and Administration
Select Disable to configure the IP parameters manually. If this option is
eters as described above.
t(s) through which the unit searches for and
selected, configure the static IP param
Select DHCP Only to cause the unit to search for and acquire its IP
parameters, including the IP address, subnet mask and default gateway, from
a DHCP (Dynamic Host Configuration Protocol) server only. If this option is
selected, you must select the por
communicates with the DHCP server, as described in section 4.2.6.1.4.2
. You do
not have to configure static IP parameters for the unit. DHCP messages are
handled by the units as management frames.
Select Automatic to cause the unit to search for a DHCP server and acquire
its IP parameters from the server. If a DCHP server is not located within
approximately 40 seconds,
the currently configured parameters are used. If
.6.1.4.2
this option is selected, you must configure the static IP parameters as
described above. In addition, you must select the port(s) through which the
unit searches for and communicates with the DHCP server, as described in
section 4.2
.
The default is Disable.
municates with a DHCP server. Select from the following
options:
From Ethernet Only
Ethernet and Wireless Link
Subscriber
4.2.6.1.5
lues of the IP parameters,
ss, Run Time Subnet Mask and Run Time
Default Gateway Address.
4.2.6.2
4.2.6.1.4.2 Access to DHCP
The Access to DHCP option enables defining the port through which the unit
searches for and com
From Wireless Link Only
From Both
The default for Access Units is From Ethernet Only. The default for
Units is From Wireless Link Only.
Show IP Parameters
The Show IP Parameters option displays the current va
including the Run Time IP Addre
Air Interface Parameters
The Air Interface Parameters menu enables viewing the current Air Interface
parameters defined for the unit and configuring new values for each of the
relevant parameters.
BreezeACCESS 4900 System Manual
92