Installation Manual

Configuring System Parameters Subscriber Unit Installation Guide
22 BreezeCOM
c) Select 1 (1Mbps) if the RSSI reading, when using the Site Survey menu, is
lower than 2.2 Volts (83 units).
8.6 Change Access Rights and Reset Unit
1. After properly configuring all system parameters, the access right should be
changed to USER to prevent users from unauthorized tampering with system
parameters. Press Esc three times to return to the main menu. Type 4 to
access the Access Control menu. Type 1 to access the Change Access Rights
menu. Type 0 to select Installer access rights allowing users only reading the
configured parameters.
2. Press Esc twice to return to main menu. Type 1 to access the System
Configuration menu. Type in 5 to access the Station Control sub-menu. Type
1 to access the Reset Unit sub-menu. Type in 1 to reset the unit so that new
configuration settings are applied.
Note: Should you make any mistake during configuration, or should you
encounter any problem associated with system configuration parameters,
you may configure the unit back to the factory defaults.
Select 2 in the Station Control menu to access the Set Factory Defaults
menu and than Type in 1 to load the default values. Select 1 in the station
control menu to access the Reset Unit, then type 1 so that the unit will be
reset in order for the factory defaults to take effect.
8.7 Voice Port Setup
Note: This setting only applies to DV series units that have a telephone
interface.
The specific configuration sequence varies according to the equipment (gateway
and gatekeeper) that is used by the Service Provider. For further information on
the Voice Port setup refer to the Telephony Application Manual.