Installation Manual
Configuring System Parameters Subscriber Unit Installation Guide
18 BreezeCOM
8.1 Setup for PC Terminal Emulation Program
Use the following setup for the ASCII terminal connection:
Baud rate 9600
Data bits 8
Stop bits 1
Parity None
Flow Control None
Connector Available Com Port
Note: Optionally, the product can be configured using Telnet over the Ethernet
port, after setting IP address. For further information refer to the
Administration Manual.
8.2 Parameters
The following system parameters must be configured for each specific installation:
• IP Address
• Subnet Mask
• Default Gateway Address
• ESS ID
• Max. Data Rate
At the end of the configuration process access rights setting should be changed to
“Installer”. It is recommended to configure system parameters at the laboratory
prior to the actual installation.
Note: You should select Reset Unit in the Station Control Sub-menu for the
changes to take effect.