Installation Manual
Subscriber Unit Installation Guide Configuring System Parameters
BreezeCOM 17
Site Survey
===========
1 - Traffic Statistics
2 - Wireless Management Statistics
3 - Print Per-Hop Statistics
4 - TCP/IP Statistics
5 - VLAN Statistics
6 - Memory Usage Statistics
7 - Average RSSI Continues Display (SU only !)
8 - MAC Address database
9 - Voice Statistics
A - Call Management Statistics
Figure 9. Site Survey Menu
4. Move the antennas until the maximum received signal strength is attained. As
you align the antennas, you will see that the RSSI (received signal strength
indicator) continually increases until it reaches a certain level after which the
RSSI begins to decrease. This is the maximum attainable RSSI level indicating
optimum receive antenna alignment.
5. For proper operation the RSSI reading should be at least 75 units. When
maximal reading is lower try to improve it through placing the antenna higher
or in a different location.
6. Tighten the U-bolts (or metal band) over the antenna to secure it to the pole.
8. Configuring System Parameters
After completing the installation process for both the Outdoor and Indoor units, as
described in the preceding sections of this manual, proceed with alignment of the
antenna and configuration of the basic system parameters.
For this configuration process, you will need to connect an ASCII terminal with
terminal emulation software (e.g., Procomm or Windows 95 HyperTerminal) to
the MON port of the Outdoor unit(s) via the supplied technician cable.