Installation Guide

Configuring System Parameters Access Unit Installation Guide
14 BreezeCOM
5. Connect a hub, switch or router to the 10-Base T connector, located on the
front panel of the Indoor unit. The cable connection should be straight.
Note: The length of the Ethernet cable, together with the length of the Baseband
cable, should not exceed 100 meters.
6. Configuring System Parameters
After completing the installation process for both the Outdoor and Indoor units, as
described in the preceding sections of this manual, proceed with configuration of
the basic system parameters.
For this configuration process, you will need to connect an ASCII terminal with
terminal emulation software (e.g., Procomm or Windows 95 HyperTerminal) to
the MON port of the Outdoor unit via the technician cable.
6.1 Setup for PC Terminal Emulation Program
Use the following setup for the ASCII terminal connection:
Baud rate 9600
Data bits 8
Stop bits 1
Parity None
Flow Control None
Connector Available Com Port
Note: Optionally, the product can be configured using Telnet over the Ethernet
port, after setting the IP address. For further information, refer to the
Administration Manual.