User manual

The Configuration page settings are explained in the following table:
Setting Function
OSD Hotkey Selects which Hotkey controls the OSD function: [Scroll Lock]
[Scroll Lock] or [Ctrl] [Ctrl]. Since the Ctrl key combination may
conflict with programs running on the computers, the default is the
Scroll Lock combination.
ID Display Selects how the Port ID is displayed: the Port Number alone
(PORT NUMBER); the Port Name alone (PORT NAME); or the
Port Number plus the Port Name (PORT NUMBER + PORT
NAME). The default is PORT NUMBER + PORT NAME).
ID Duration Determines how long a Port ID displays on the monitor after a port
change has taken place. You can choose an amount from 1 - 255
seconds. The default is 3 Seconds.
Scan Select Selects which computers will be accessed under Auto Scan Mode
(see pp. 34 and 35). Choices are: ALL - All the Ports which have
been set Accessible (see p. 15); POWERED ON - Only those Ports
which have been set Accessible and are Powered On; QUICK
VIEW - Only those Ports which have been set Accessible and have
been selected as Quick View Ports (see p. 21); QUICK VIEW +
POWERED ON - Only those Ports which have been set Accessible
and have been selected as Quick View Ports and are Powered On.
The default is ALL.
Scan Duration Determines how long the focus dwells on each port as it cycles
through the selected ports in Auto Scan Mode (see pp. 34 and 35).
Key in a value from 1 - 255 seconds. The default is 5 seconds; a
setting of 0 disables the Scan function.
Screen Blanker If there is no input from the console for the amount of time set with
this function, the screen is blanked. Key in a value from 1 - 30
minutes. A setting of 0 disables this function. The default is 0
(disabled).
Logout Timeout If there is no Operator input for the amount of time set with this
function, the Operator is automatically logged out. A login is
necessary before the KN9116 can be accessed again.
Beeper When set to ON, the beeper sounds whenever a Port is changed;
when activating the Auto Scan function (see pp. 34 and 35); or an
invalid entry is made on an OSD menu. The default is ON.