Overview:
WayPoint Outdoor Power Supplies provide 24VAC and/or 28VAC distributed via two (2), four (4) or eight (8) output(s)
for powering CCTV Cameras, heaters, and other video accessories.
WayPoint AC Reference Chart:
Altronix
Model Number
Output Voltage
Total
Output
Current
(Power)
Number
and Type
of Outputs
Fuse
Output
Ratings
PTC
Output
Ratings
Input Current Draw
Product
Weight
115VAC
60Hz
230VAC
50Hz
WayPoint30ADU
24VAC 12.5 amp
2
10 amp/
32V
-----
3.0 amp 1.5 amp
4.68kg28VAC 10 amp
24VAC and 28VAC 10 amp 1 of each
WayPoint30A4U
24VAC 12.5 amp
4 Fused
5 amp/
32V
----- 4.68kg
28VAC 10 amp
WayPoint30A4DU
24VAC 10 amp
4 PTCs ----- 2.5 amp 4.68kg
28VAC 10 amp
WayPoint30A8U
24VAC 12.5 amp
8 Fused
5 amp/
32V
----- 4.8kg
28VAC 10 amp
WayPoint30A8DU
24VAC 12.5 amp
8 PTCs ----- 2.5 amp 4.8kg
28VAC 10 amp
*Lower rated fuses can be used.
Specifications:
Installation Instructions:
Unit should be installed in accordance with The National Electrical Code and all applicable Local Regulations.
1. Remove back plane from enclosure prior to mounting (do not discard hardware).
2. Mark and drill desired inlets on the enclosure to facilitate wiring (Fig. 1, pg. 3).
3. Mount unit in desired location. Mark and drill holes to line up with the top and bottom holes of the enclosure flange.
Secure enclosure with appropriate fasteners (Fig. 5, pg. 7 and Fig. 11, pg. 8).
4. Mount back plane to enclosure with hardware.
5. Set the input voltage selector switch for 115VAC or 230VAC operation (Figs. 2-4, pgs. 4-6)
6. To facilitate wire entry utilize weather-tight NEMA 4 rated connectors, bushings, and cable.
7. Set illuminated master power disconnect circuit breaker to the [OFF] position (Figs. 2-4, pgs. 4-6).
8. Connect unswitched AC power (115VAC/230VAC 50/60 Hz) to terminals marked [L, N] (Figs. 2-4, pgs. 4-6).
Green branch wire connects to earth (safety) ground lug .
Wire gauge range of connectors is 14 AWG to 11 AWG (1.6 mm to 2.5 mm diameter).
9. Set illuminated master power disconnect circuit breaker to the (RESET/ON) position (Figs. 2-4, pgs. 4-6).
10. WayPoint30A4U/A4DU, WayPoint30A8U/A8DU are factory set for 24VAC operation.
For 28VAC operation adjust unit prior to mounting and applying power as follows:
Change the wire position so that the black wire [28V] is connected to the terminal marked [P] and
the yellow wire [24V] is connected to the terminal marked [S].
11. Measure output voltage on terminals marked [COM, 24V, 28V] on WayPoint30ADU (Fig. 2, pg. 4)
or [1-4 or 1-8 COM] on WayPoint30A4U, WayPoint30A4DU, WayPoint30A8U and WayPoint30A8DU before
connecting devices (Fig. 3, pg. 5, Fig. 4, pg. 6). This helps avoiding potential damage.
Agency Listings:
• UL Listed for Information Technology Equipment
(UL 60950-1) and Equipment to be Installed Outdoors
(UL 60950-22).
• CE European Conformity.
Input:
• Input: 115VAC 60Hz, 3 amp or 230VAC 50Hz, 1.5 amp.
Output:
• Output options:
a. 24VAC or 28VAC.
b. Both 24VAC and 28VAC (WayPoint30ADU only).
• Fuse ratings:
WayPoint30A4U and WayPoint30A8U: 5A.
Visual Indicators:
• Individual power output LED indicators.
• Illuminated master power switch.
Features:
• Surge suppression.
• Spare fuses included.
Accessories:
• Optional PMK1 Pole Mount Kit simplifies installation of
outdoor units.
Enclosure:
• NEMA 4/4X, IP66-11 Rated enclosure for outdoor use.
• Enclosure Dimensions (H x W x D approx.):
13.31” x 11.31” x 5.59”
(338.074 mm x 287.274 mm x 141.986 mm).