Installation Guide
- 2 - T2MK Kits
Overview:
Altronix Trove Mercury kits are pre-assembled and consist of Trove2M2 enclosure/backplane with factory installed Altronix power
supply/charger(s) and sub-assemblies. These kits also accommodate various combinations of Mercury boards for up to sixteen (16) doors
in a single enclosure.
Configuration Chart:
Altronix
Model Number
Nominal DC Output
Voltage
Maximum Supply
Current for Main
and Aux. Outputs
on Power Supply
board and ACM4/
ACM8 Access Power
Controller’s outputs
Fail-Safe/Fail-Secure or
Dry Form “C” Outputs
120VAC 60Hz
Input Current (A)
Current Per
ACM4/ACM8 Output (A)
Power Supply Board
Input Fuse Rating
Power Supply Board
Battery Fuse Rating
ACM4/ACM8 Board
Input Fuse Rating
ACM4/ACM8 Board
Output Fuse Rating
PDS8 Board
Input Fuse Rating
PDS8 Board
Output Fuse Rating
PD8UL Board
Output Fuse Rating
Power
Supply 1
Power
Supply 2
[DC] [Aux] [DC] [Aux]
Output Range
(VDC)
Output Range
(VDC)
Output Range
(VDC)
Output Range
(VDC)
T2MK3F4
20.19-
26.4
20.19-
26.4
– – 24VDC @ 5.8A 4 3.5 2.5
5A/
250V
10A/
32V
10A/
250V
3A/
250V
10A/
250V
3A/
250V
–
T2MK3F4Q
20.19-
26.4
20.19-
26.4
– – 24VDC @ 5.8A 4 3.5 2.5
5A/
250V
10A/
32V
10A/
250V
3A/
250V
10A/
250V
3A/
250V
–
T2MK3F8
20.19-
26.4
20.19-
26.4
– – 24VDC @ 5.8A 8 3.5 2.5
5A/
250V
10A/
32V
10A/
250V
2.5A/
250V
10A/
250V
3A/
250V
–
T2MK3F8Q
20.19-
26.4
20.19-
26.4
– – 24VDC @ 5.8A 8 3.5 2.5
5A/
250V
10A/
32V
10A/
250V
2.5A/
250V
10A/
250V
3A/
250V
–
T2MK7F8
20.17-
26.4
20.28-
26.4
– – 24VDC @ 9.2A 8 4.5 2.5
6.3A/
250V
15A/
32V
10A/
250V
2.5A/
250V
10A/
250V
3A/
250V
–
T2MK7F8Q
20.17-
26.4
20.28-
26.4
– – 24VDC @ 9.2A 8 4.5 2.5
6.3A/
250V
15A/
32V
10A/
250V
2.5A/
250V
10A/
250V
3A/
250V
–
T2MK75F16
20.17-
26.4
20.28-
26.4
9.7-
13.2
10.03-
13.2
12VDC @ 9.3A
24VDC @ 9.2A
16 8 2.5
6.3A/250V
5A/250V
15A/
32V
10A/
250V
2.5A/
250V
– –
3.5A/
250V
T2MK75F16Q
20.17-
26.4
20.28-
26.4
9.7-
13.2
10.03-
13.2
12VDC @ 9.3A
24VDC @ 9.2A
16 8 2.5
6.3A/250V
5A/250V
15A/
32V
10A/
250V
2.5A/
250V
– –
3.5A/
250V
T2MK77F16
20.17-
26.4
20.28-
26.4
20.17-
26.4
20.28-
26.4
24VDC @ 9.2A 16 9 2.5
6.3A/
250V
15A/
32V
10A/
250V
2.5A/
250V
10A/
250V
3A/
250V
–
T2MK77F16Q
20.17-
26.4
20.28-
26.4
20.17-
26.4
20.28-
26.4
24VDC @ 9.2A 16 9 2.5
6.3A/
250V
15A/
32V
10A/
250V
2.5A/
250V
10A/
250V
3A/
250V
–
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having
jurisdiction. Product is intended for indoor use only.
1. Remove backplane(s) from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws
in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper screws, level and secure.
Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the
enclosure’s upper keyholes over the three upper screws. Install the three lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch (Honeywell Model 112 or equivalent) in desired location, opposite hinge. Slide the
tamper switch bracket onto the edge of the enclosure approximately 2” from the right side
(Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or the
appropriate UL Listed reporting device. To activate alarm signal open the
door of the enclosure.
4. Refer to the eFlow Power Supply/Charger Installation Guide (eFlow6NB, eFlow102NB,
eFlow104NB) and Sub-Assembly Installation Guide for the following models:
ACM4, ACM8, LINQ2, PDS8, VR6 for further installation instructions.
5. Fasten snap on standoffs onto metal pems configuration of backplane depending on the
Mercury access controller (Fig. 2-5, pg. 3-6).
6. Position Mercury access controller module over corresponding standoffs and depress onto
snap on standoffs (Fig. 2-5, pg. 3-6).
7. Mount backplane to enclosure with hardware.
Edge of
Enclosure
to Access Control Panel
or U.L. Listed
Reporting Device
Enclosure
Honeywell
model # 112
Tamper Switch
or equivalent
(provided)
Fig. 1