Installation Instructions User guide

Open Frame Transformers
Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
website: www.altronix.com, e-mail: info@altronix.com, Made in U.S.A.
IITransformers - Rev. 110201
MEMBER
Specification Chart (all transformers listed are 120VAC input):
Model # Output Amp A B C D E F Approx. Ship Wt.
T1656 16VAC/56VA 3.50 2.75” 2.25” 1.87” 1.06” 3.75” 3.12” 1.4 oz.
T16100 16VAC/100VA 6.25 3.06” 2.56” 2.25” 1.31” 4” 3.625” 1.17 lbs.
T24130 24VAC/100VA 4.16 3.06” 2.56” 2.25” 1.31” 4” 3.625” 1.12 lbs.
T2856 28VAC/56VA 2.00 2.75” 2.25” 1.87” 1.06” 3.75” 3.12” 1.8 oz.
T2885 28VAC/100VA 4.16 3.57” 2.56” 2.25” 1.31” 4” 3.625” 1.12 lbs.
Installation Instructions:
1. Mount Transformer in desired location/enclosure.
2. Plug in the AC (120VAC 50 / 60 Hz) to an outlet.
Note: It is important to measure output voltage before connecting devices. This helps avoid potential damage.
3. Connect devices to secondary terminals on the transformer.
WARNING: This installation should be made by qualified service personnel and should
conform to all local codes and in accordance with the National Electrical Codes.
Fig. 1
10 9 8 7 6
PRIMARY TERMINALS
SECONDARY TERMINALS
F
5 4 3 2 1
A
B
D
C
E

Summary of content (1 pages)