Installation Guide

- 2 - StrikeIt4
Overview:
Altronix StrikeIt4 will operate up to two (2) low current lock hardware devices simultaneously. It is designed to
operate motorized electric latch retraction exit devices, electric strikes, mag-locks, electric mortise and cylindrical
locksets, etc. Each lock output has an adjustable re-lock delay timer. It will control a pair of doors simultaneously,
or independently control two single door leafs. StrikeIt4 has integrated output relays which trigger automatic door
operators and control ADA activation push plates/accessories. In addition, one (1) 12VDC and one (1) 24VDC
unswitched auxiliary voltage outputs are provided for powering ancillary devices. A configurable FACP interface
will either remove or apply power from the lock outputs when activated. LED status indicators are provided to
monitor input status, battery condition, AC power loss, and FACP status. Intelligent logic provides protection
against accidental shorting of lock outputs.
Specifications:
Agency Approval:
UL 294* Access Control Unit Power Supply.
ULC-S319 Access Control Unit Power Supply.
Class 1.
Input:
Input 115VAC, 60Hz, 2.5A or 230VAC, 50Hz, 1.5A.
Two (2) Normally Open (N.O.) trigger inputs
(Input 1 and Input 2).
FACP Normally Closed (N.C.) input.
Two normally open ADA inputs for special mode of
interfacing with automatic door operators.
Outputs:
Two (2) 19.8VDC-26.4VDC rated individually
controlled lock outputs configurable for fail-secure
or fail-safe electronic locking hardware for
applications with battery back-up.
24VDC-26.4VDC rated for applications without
battery back-up (US applications only).
Current rating 2A combined.
One (1) 19.8VDC-26.4VDC @ 0.8A rated filtered
regulated auxiliary output for applications with
battery back-up,
24VDC-26.4VDC @ 0.8A rated for applications in
US not requiring battery back-up.
Not affected by FACP trigger.
One (1) 12VDC filtered regulated auxiliary output
rated 0.5A. Not affected by FACP trigger.
Two (2) follower Normally Open relay outputs for
controlling ADA actuators/accessories rated
28VDC @ 0.5A.
Outputs (cont’d):
Two momentary door operator activation
relay outputs.
Trouble relay output indicating low AC voltage
trouble and battery trouble.
Battery Backup:
Requires two (2) 12V batteries to be wired in series
for 24V operation.
When 7AH batteries are used, battery capacity
for emergency stand-by is 30 minutes.
Built-in charger for sealed lead acid batteries.
Maximum charge current 650mA.
Automatic switch over to stand-by battery
when AC fails.
Battery PTC rating: 6A.
Battery leads included.
Visual Indicators:
Green AC Power LED indicates AC presence.
Red trigger output LEDs indicate panic device
status / opened (activated, short circuit).
Green Fire Alarm Interface (FAI) LED indicates
FACP interface is activated.
Red Battery LED indicates low battery during
AC failure and battery test.
Green AC status LED indicates loss of AC power.
Enclosure Dimensions (H x W x D approx.):
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.6mm)
* Access Control Performance Levels: Destructive Attack - I; Endurance - IV; Line Security - I; Stand-by Power - II.