Installation Instructions
PD8CB - Power Distribution Module
Overview:
The PD8CB power distribution module converts a single AC or DC output into eight (8) PTC protected outputs.
Specifications:
Input:
• 28VACor28VDCupto12amp.
Output:
• Eight(8)PTCprotectedoutputs(PTCsarerated@2.5amp).
• Surgesuppression.
Visual Indicators:
•PoweroutputLEDindicator.
Additional Features:
•PowerON/OFFswitch.
Board Dimensions (W x L x H approximate):
3.25”x5.25”x1”(82.55mmx133.35mmx25.4mm).
Installation Instructions:
1. MountPD8CBinthedesiredlocation/enclosure.
2. Connectthedesiredpowersupplyoutputtotheterminalsmarked[INPUT](Fig. 1a).
3. IfusingDCvoltage,leftterminalisNEG.(-)andrightterminalisPOS.(+)(Fig. 1a).
4. Measureoutputvoltagebeforeconnectingdevices.Thishelpsavoidingpotentialdamage.
AllterminalswithcommonsuffixP1P,2P...”arethesamepolarity.
5. Setpowerswitch[SW1]totheOFFposition.
6. Connecteachdevicetoterminalpairs1to8marked[1P-1N]through[8P-8N].
7. Setpowerswitch[SW1]totheONposition.
N
COMMON POWER OUTPUTS
P
FUSED POWER OUTPUTS
D1
INPUT
R1
LED
SW1
ON OFF
F1 F2 F3 F4 F5 F6 F7 F8
1 2 3 4 5 6 7 8
N
P
S
Main Fuse
Altronixisnotresponsibleforanytypographicalerrors.Productspecificationsaresubjecttochangewithoutnotice.
14058thStreet,Brooklyn,NewYork11220USA,718-567-8181,fax:718-567-9056
website:www.altronix.com,e-mail:info@altronix.com,LifetimeWarranty,MadeinU.S.A.
IIPD8CB-Rev.111704 K18M
MEMBER
Fig. 1
N
COMMON POWER OUTPUTS
P
FUSED POWER OUTPUTS
D1
INPUT
R1
LED
SW1
ON OFF
F1 F2 F3 F4 F5 F6 F7 F8
1 2 3 4 5 6 7 8
N
P
S
Main Fuse
Neg. (--- )
Pos. (+ )
Fig. 1a