Power Distance Chart
Power Requirements Power Cabling Maximum Distance (ft./m)
15W 12/2 11,162’ / 3403m
30W 12/2 5,581’ / 1702m
45W 12/2 3,767 / 1,148m
60W 12/2 2,739’ / 835m
75W 12/2 2,249’ / 686m
90W 12/2 1,872’ / 571m
105W 12/2 1,607’ / 490m
120W 12/2 1,408’ / 429m
15W 16/2 4,415’ / 1,346m
30W 16/2 2,207’ / 673m
45W 16/2 1,490’ / 454m
60W 16/2 1,083’ / 330m
75W 16/2 889’ / 271m
90W 16/2 740’ / 226m
105W 16/2 635’ / 194m
120W 16/2 557’ / 170m
Estimated distances based on starting voltage of 56VDC and accounts for a 10 volt drop.
All distances are per IEEE 802.3at standard for device power requirements of minimum
44VDC and leave an approximate 2 volts for safety and flexibility.